• Norah (pup/it/she)@lemmy.blahaj.zone
    link
    fedilink
    English
    arrow-up
    8
    ·
    11 个月前

    The live and neutral pins are wired together, so there’s not really a reason for the power to travel to that ground wire. Unless the path to the ground of the device, and then from there to actual ground, is shorter, then nothing will flow that way. It’s absolutely not safe, but a number of other factors would need to be present before it were deadly.

    • Darkassassin07@lemmy.ca
      link
      fedilink
      English
      arrow-up
      18
      ·
      11 个月前

      Unless the path to the ground of the device, and then from there to actual ground, is shorter, then nothing will flow that way.

      That’s not true. Electricity will take all available paths to return to ground, with current flow relative to the resistance present. In other words, two low resistance paths will share similar amounts of current when both are connected to power.

      If you were touching anything connected to that ‘ground’ wire while also connected to a true ground yourself; you could receive a harmful shock from plugging this in, even with a breaker in-line and successfully tripping. A GFCI device should prevent that shock, but a regular breaker will not trip fast enough.

      • Norah (pup/it/she)@lemmy.blahaj.zone
        link
        fedilink
        English
        arrow-up
        4
        ·
        edit-2
        11 个月前

        True actually. If this were the plug for a washing machine, and you were touching it and the tap for the water inlet, you would definitely get shocked still. Edit: The washing machine itself also wouldn’t generally have a connection to ground that way, as they usually use plastic hoses.