      This is a plug, not an outlet; and it shorts the live + neutral pins together. There is no ground pin present, though a wire labeled ground is also being shorted to the live+neutral pins. (basing ‘pins’ on shape/colour and ignoring that at least one is in the wrong position)

      If this doesn’t immediately trip the breaker when plugged in, it’s because you have an open neutral; and now whatever’s on the end of that ground wire (typically exposed metal) is live.

      • Norah (pup/it/she)@lemmy.blahaj.zone
        link
        fedilink
        English
        arrow-up
        8
        ·
        11 months ago

        The live and neutral pins are wired together, so there’s not really a reason for the power to travel to that ground wire. Unless the path to the ground of the device, and then from there to actual ground, is shorter, then nothing will flow that way. It’s absolutely not safe, but a number of other factors would need to be present before it were deadly.

        • Darkassassin07@lemmy.ca
          link
          fedilink
          English
          arrow-up
          18
          ·
          11 months ago

          Unless the path to the ground of the device, and then from there to actual ground, is shorter, then nothing will flow that way.

          That’s not true. Electricity will take all available paths to return to ground, with current flow relative to the resistance present. In other words, two low resistance paths will share similar amounts of current when both are connected to power.

          If you were touching anything connected to that ‘ground’ wire while also connected to a true ground yourself; you could receive a harmful shock from plugging this in, even with a breaker in-line and successfully tripping. A GFCI device should prevent that shock, but a regular breaker will not trip fast enough.

          • Norah (pup/it/she)@lemmy.blahaj.zone
            link
            fedilink
            English
            arrow-up
            4
            ·
            edit-2
            11 months ago

            True actually. If this were the plug for a washing machine, and you were touching it and the tap for the water inlet, you would definitely get shocked still. Edit: The washing machine itself also wouldn’t generally have a connection to ground that way, as they usually use plastic hoses.

    • Undearius@lemmy.ca
      link
      fedilink
      English
      arrow-up
      13
      ·
      11 months ago

      I wouldn’t say connecting the ground wire of an appliance to the hot side of an outlet is very safe.

    • takeda@lemmy.dbzer0.com
      link
      fedilink
      arrow-up
      4
      ·
      edit-2
      11 months ago

      This picture doesn’t show how to wire socket, but now to wire a plug. The wire that’s labeled ground is actually attached to live connector, although I guess that doesn’t matter as live and neutral are shorted by white wire.

        • ladicius@lemmy.world
          link
          fedilink
          arrow-up
          2
          ·
          11 months ago

          And where does phase go to or come from? The picture shows a short of piece of wire labelled “phase” but that doesn’t magically make an otherwise unconnected piece of wire anything active. If labelling anything “phase” could produce energy, boy would my energy bill go down fast 😂

          I keep to my statement: The pic shows a completely dead “circuit”.

          • Ilovethebomb@sh.itjust.works
            link
            fedilink
            arrow-up
            3
            ·
            edit-2
            11 months ago

            This is a plug, which you plug into a socket, which is where the leccy comes from.

            Of course the circuit is dead, it’s not plugged in.